Solution Manual For Materials For Civil And Construction Engineers, 3rd Edition
- Civil Engineering
- 105 pages
- Shared May 2025
Solution Manual For Materials For Civil And Construction Engineers, 3rd Edition makes textbook problem-solving easy with a comprehensive guide that explains every step.
Preview 16 of 105 pages
See the first 16 pages exactly as they appear in the document.
Page 1 Read page 1 as text
1 CHAPTER 1. MATERIALS ENGINEERING CONCEPTS 1.2. Strength at rupture = 45 ksi Toughness = (45 x 0.003) / 2 = 0.0675 ksi 1.3. A = 0.36 in 2 = 138.8889 ksi A = 0.0035 in/in L = -0.016667 in/in E = 39682 ksi = 0.21 1.4. A = 201.06 mm 2 = 0.945 GPa A = 0.002698 m/m L = -0.000625 m/m E = 350.3 GPa = 0.23 1.5. A = d 2 /4 = 28.27 in 2 -150,000 / 28.27 in 2 = -5.31 ksi E = = 8000 ksi A / E = -5.31 ksi / 8000 ksi = -0.0006631 in/in L = A o = -0006631 in/in (12 in) = -0.00796 in L f = L + L o = 12 in – 0.00796 in = 11.992 in = - L / A = 0.35 L d / d o = - A = -0.35 (-0.0006631 in/in) = 0.000232 in/in d = L o = 0.000232 (6 in) = 0.00139 in d f = d + d o = 6 in + 0.00139 in = 6.00139 in 1.6. A = d 2 /4 = 0.196 in 2 2 = 10.18 ksi (Less than the yield strength. Within the elastic region) E = = 10,000 ksi A / E = 10.18 ksi / 10,000 ksi = 0.0010186 in/in L = A o = 0.0010186 in/in (12 in) = 0.0122 in L f = L + L o = 12 in + 0.0122 in = 12.0122 in = - L / A = 0.33 L d / d o = - A = -0.33 (0.0010186 in/in) = -0.000336 in/in d = L o = -0.000336 (0.5 in) = -0.000168 in d f = d + d o = 0.5 in - 0.000168 in = 0. 49998 in 12 in 6 in 12 in 6 in
Page 2 Page 3 Read page 3 as text
2 1.7. L x =30 mm, L y = 60 mm, L z = 90 mm x = y = z = = 100 MPa E = 70 GPa = 0.333 x = [ x - ( y + z ) ] /E x = [100 x 10 6 - 0.333 (100 x 10 6 + 100 x 10 6 )] / 70 x 10 9 = 4.77 x 10 - 4 = y = z = L x = x L x = 4.77 x 10 -4 x 30 = 0.01431 mm L y = x L y = 4.77 x 10 -4 x 60 = 0.02862 mm L z = x L z = 4.77 x 10 -4 x 90 = 0.04293 mm V = New volume - Original volume = [(L x - L x ) (L y - L y ) (L z - L z )] - L x L y L z = (30 - 0.01431) (60 - 0.02862) (90 - 0.04293)] - (30 x 60 x 90) = 161768 - 162000 = -232 mm 3 1.8. L x =4 in, L y = 4 in, L z = 4 in x = y = z = = 15,000 psi E = 1000 ksi = 0.49 x = [ x - ( y + z ) ] /E x = [15 - 0.49 (15 + 15)] / 1000 = 0.0003 = y = z = L x = x L x = 0.0003 x 15 = 0.0045 in L y = x L y = 0.0003 x 15 = 0.0045 in L z = x L z = 0.0003 x 15 = 0.0045 in V = New volume - Original volume = [(L x - L x ) (L y - L y ) (L z - L z )] - L x L y L z = (15 - 0.0045) (15 - 0.0045) (15 - 0.0045)] - (15 x 15 x 15) = 3371.963 - 3375 = -3.037 in 3 1.9. = 0.3 x 10 -16 3 At = 50,000 psi, = 0.3 x 10 -16 (50,000) 3 = 3.75 x 10 -3 in./in. Secant Modulus = 50 000 3 75 10 3 , . x = 1.33 x 10 7 psi d d 0.9 x 10 -16 2 At = 50,000 psi, d d 0.9 x 10 -16 (50,000) 2 = 2.25 x 10 -7 in. 2 /lb Tangent modulus = d d x 1 2 25 10 7 . = 4.44x10 6 psi
Page 4 Read page 4 as text
3 1.11. lateral = 1 10 25 . 3 4 x = -3.25 x 10 -4 in./in. axial = 2 10 2 3 x = 1 x 10 -3 in./in. = lateral axial x x 325 10 1 10 4 3 . = 0.325 1.12. lateral = 0.05 / 50 = 0.001 in./in. axial = x lateral = 0.33 x 0.001 = 0.00303 in. d = axial x d 0 = - 0.00825 in. (Contraction) 1.13. L = 380 mm D = 10 mm P = 24.5 kN = P/A = P/ r 2 = 24,500 N/ (5 mm) 2 = 312,000 N/mm 2 = 312 MPa = PL AE lbx mm mm E kPa E MPa 24 500 380 118 539 2 , (5 ) ( ) , ( ) mm Material Elastic Modulus (MPa) Yield Strength (MPa) Tensile Strength (MPa) Stress (MPa) (mm) Copper 110,000 248 289 312 1.078 Al. alloy 70,000 255 420 312 1.693 Steel 207,000 448 551 312 0.573 Brass alloy 101,000 345 420 312 1.174 The problem requires the following two conditions: a) No plastic deformation Stress < Yield Strength b) Increase in length, < 0.9 mm The only material that satisfies both conditions is steel . 1.14. a. E = / = 40,000 / 0.004 = 10 x 10 6 psi b. Tangent modulus at a stress of 45,000 psi is the slope of the tangent at that stress = 4.7 x 10 6 psi c. Yield stress using an offset of 0.002 strain = 49,000 psi d. Maximum working stress = Failure stress / Factor of safety = 49,000 / 1.5 = 32,670 psi
Page 5 Read page 5 as text
4 1.15.a. Modulus of elasticity within the linear portion = 20,000 ksi. b.Yield stress at an offset strain of 0.002 in./in. 70.0 ksi c.Yield stress at an extension strain of 0.005 in/in. 69.5 ksi d. Secant modulus at a stress of 62 ksi. 18,000 ksi e. Tangent modulus at a stress of 65 ksi. 6,000 ksi 1.16.a. Modulus of resilience = the area under the elastic portion of the stress strain curve = ½(50 x 0.0025) 0.0625 ksi b. Toughness = the area under the stress strain curve (using the trapezoidal integration technique) 0.69 ksi c = 40 ksi , this stress is within the elastic range, therefore, E = 20,000 ksi axial = 40/20,000 = 0.002 in./in. = 002 . 0 00057 . 0 axial lateral = 0.285 d. The permanent strain at 70 ksi = 0.0018 in./in. 1.17. Material A Material B a. Proportional limit 51 ksi 40 ksi b. Yield stress at an offset strain of 0.002 in./in. 63 ksi 52 ksi c. Ultimate strength 132 ksi 73 ksi d. Modulus of resilience 0.065 ksi 0.07 ksi e. Toughness 8.2 ksi 7.5 ksi f. Material B is more ductile as it undergoes more deformation before failure 1.18. Assume that the stress is within the linear elastic range. 10 000 , 16 3 . 0 . . x l E E 480 ksi Thus > yield Therefore, the applied stress is not within the linear elastic region and it is not possible to compute the magnitude of the load that is necessary to produce the change in length based on the given information.
Page 6 Read page 6 as text
5 1.19. Assume that the stress is within the linear elastic range. 250 000 , 105 6 . 7 . . x l E E 3,192 MPa Thus > yield Therefore, the applied stress is not within the linear elastic region and it is not possible to compute the magnitude of the load that is necessary to produce the change in length based on the given information. 1.20. At = 60,000 psi, = / E = 60,000 / (30 x 10 6 ) = 0.002 in./in. a. For a strain of 0.001 in./in.: = E = 0.001 x 30 x 10 6 = 30,000 psi ( for both i and ii) b. For a strain of 0.004 in./in.: = 60,000 psi (for i) = 60,000 + 2 x 10 6 (0.004 - 0.002) = 64,000 psi ( for ii) 1.21. a. Slope of the elastic portion = 600/0.003 = 2x10 5 MPa Slope of the plastic portion = (800-600)/(0.07-0.003) = 2,985 MPa Strain at 650 MPa = 0.003 + (650-600)/2,985 = 0.0198 m/m Permanent strain at 650 MPa = 0.0198 – 650/(2x10 5 ) = 0.0165 m/m b. Percent increase in yield strength = = 100(650-600)/600 = 8.3% c. The strain at 625 MPa = 625/(2x10 5 ) = 0.003125 m/m This strain is elastic. 1.22. See Sections 1.2.3, 1.2.4 and 1.2.5.
Page 7 Read page 7 as text
6 1.23. The stresses and strains can be calculated as follows: = P/A o = 150 / ( x 2 2 ) = 11.94 psi = (H o -H)/H o = (6-H)/6 The stresses and strains are shown in the following table: Time (min.) H (in.) Strain (in./in.) Stress (psi) 0 6 0.00000 11.9366 0.01 5.9916 0.00140 11.9366 2 5.987 0.00217 11.9366 5 5.9833 0.00278 11.9366 10 5.9796 0.00340 11.9366 20 5.9753 0.00412 11.9366 30 5.9725 0.00458 11.9366 40 5.9708 0.00487 11.9366 50 5.9696 0.00507 11.9366 60 5.9688 0.00520 11.9366 60.01 5.9772 0.00380 0.0000 62 5.9807 0.00322 0.0000 65 5.9841 0.00265 0.0000 70 5.9879 0.00202 0.0000 80 5.9926 0.00123 0.0000 90 5.9942 0.00097 0.0000 100 5.9954 0.00077 0.0000 110 5.9959 0.00068 0.0000 120 5.9964 0.00060 0.0000
Page 8 Read page 8 as text
7 a. Stress versus time plot for the asphalt concrete sample Strain versus time plot for the asphalt concrete sample b. Elastic strain = 0.0014 in./in. c. The permanent strain at the end of the experiment = 0.0006 in./in. d. The phenomenon of the change of specimen height during static loading is called creep while the phenomenon of the change of specimen height during unloading called is called recovery. 0 2 4 6 8 10 12 14 0 50 100 150 Stress, psi Time, minutes 0.000 0.001 0.002 0.003 0.004 0.005 0.006 0 50 100 150 Strain, in./in. Time, minutes
Page 9 Read page 9 as text
8 1.24. See Figure 1.12(a). 1.25 See Section 1.2.7. 1.27. a. For P = 5 kN Stress = P / A = 5000 / ( x 5 2 ) = 63.7 N/mm 2 = 63.7 MPa Stress / Strength = 63.7 / 290 = 0.22 From Figure 1.16, an unlimited number of repetitions can be applied without fatigue failure. b. For P = 11 kN Stress = P / A = 11000 / ( x 5 2 ) = 140.1 N/mm 2 = 140.1 MPa Stress / Strength = 140.1 / 290 = 0.48 From Figure 1.16, N 700 1.28 See Section 1.2.8. 1.29. Material Specific Gravity Steel 7.9 Aluminum 2.7 Aggregates 2.6 - 2.7 Concrete 2.4 Asphalt cement 1 - 1.1 1.30 See Section 1.3.2. 1.31. L = L x T x L = 12.5E-06 x (115-15) x 200/1000 = 0.00025 m = 250 microns Rod length = L + L = 200,000+ 250 = 200,250 microns Compute change in diameter linear method d = d x T x d = 12.5E-06 x (115-15) x 20 = 0.025 mm Final d = 20.025 mm Compute change in diameter volume method V = V x T x V = (3 x 12.5E-06) x (115-15) x (10/1000) 2 x 200/1000 = 2.3562 x 10 11 m 3 Rod final volume = V + V = r 2 L + V x + 2.3562 x 10 11 = 6.31 x 10 13 m 3 Final d = 20.025 mm There is no stress acting on the rod because the rod is free to move.
Page 10 Read page 10 as text
9 1.32. Since the rod is snugly fitted against two immovable nonconducting walls, the length of the rod will not change, L = 200 mm From problem 1.25, L = 0.00025 m = L / L = 0.00025 / 0.2 = 0.00125 m/m = E = 0.00125 x 207,000 = 258.75 MPa The stress induced in the bar will be compression. 1.33. a. The change in length can be calculated using Equation 1.9 as follows: L = L x T x L = 1.1E-5 x (5 - 40) x 4 = -0.00154 m b. The tension load needed to return the length to the original value of 4 meters can be calculated as follows: = L / L = -0.00154/ 4 = -0.000358 m/m = E = -0.000358 x 200,000 = -77 MPa P = x A = -77 x (100 x 50) = -385,000 N = -385 kN (tension) c. Longitudinal strain under this load = 0.000358 m/m 1.34. If the bar was fixed at one end and free at the other end, the bar would have contracted and no stresses would have developed. In that case, the change in length can be calculated using Equation 1.9 as follows. L = L x T x L = 0.000005 x (0 - 100) x 50 = -0.025 in. = L / L = 0.025 / 50 = 0.0005 in./in. Since the bar is fixed at both ends, the length of the bar will not change. Therefore, a tensile stress will develop in the bar as follows. = E = -0.0005 x 5,000,000 = -2,500 psi Thus, the tensile strength should be larger than 2,500 psi in order to prevent cracking. 1.36 See Section 1.7. 1.37 See Section 1.7.1 1.38. H o : 32.4 MPa H 1 : 32.4 MPa = 0.05 T o = x n ( / ) = -3 Degree of freedom = = n - 1 = 15 From the statistical t-distribution table, T , = T 0.05, 15 = -1.753 T o < T , Therefore, reject the hypothesis. The contractor’s claim is not valid.
Page 11 Read page 11 as text
10 1.39. H o : 5,000 psi H 1 : 5,000 psi = 0.05 T o = x n ( / ) = -2.236 Degree of freedom = = n - 1 = 19 From the statistical t-distribution table, T , = T 0.05, 19 = -1.729 T o < T , Therefore, reject the hypothesis. The contractor’s claim is not valid. 1.40. psi x n x x i i n i i 25 . 698 , 5 20 965 , 113 20 20 1 1 psi x n x x s i i n i i 35 . 571 1 20 ) 25 . 5698 ( 1 ) ( 2 / 1 20 1 2 2 / 1 1 2 Coefficient of Variation = % 03 . 10 25 . 5698 35 . 571 100 100 x s b. The control chart is shown below. The target value is any value above the specification limit of 5,000 psi. The plant production is meeting the specification requirement.
Page 12 Read page 12 as text
11 1.41. a. 20 7 . 110 20 20 1 1 i i n i i x n x x 5.5 % 2 / 1 20 1 2 2 / 1 1 2 1 20 ) 5 . 5 ( 1 ) ( i i n i i x n x x s 0.33 % 5 . 5 33 . 0 100 100 x s C 6 % b. The control chart is shown below. The control chart shows that most of the samples have asphalt content within the specification limits. Only few samples are outside the limits. The plot shows no specific trend, but large variability especially in the last several samples. 1.42 See Section 1.8.2. 1.43 See Section 1.8. 4.5 5.0 5.5 6.0 6.5 0 5 10 15 20 25 Asphalt Content, % Sample No. UCL = 5.9 LCL = 5.1 Target = 5.5
Page 13 Read page 13 as text
12 1.44. a. No information is given about accuracy. b. Sensitivity == 0.001 in. c. Range = 0 – 1 inch d. Accuracy can be improved by calibration. 1.45. a. 0.001 in. b. 100 psi c. 100 MPa d. 0.1 ge. 10 psi f. 0.1 % g. 0.1 % h. 0.001 i. 100 miles j. 10 -6 mm
Page 14 Read page 14 as text
13 1.46 The voltage is plotted versus displacement is shown below. From the figure: Linear range = 0.1 in. Calibration factor = 101.2 Volts/in. 1.47 The voltage is plotted versus displacement is shown below. From the figure: Linear range = 0.3 in. Calibration factor = 1.47 Volts/in. -15 -10 -5 0 5 10 15 -0.15 -0.1 -0.05 0 0.05 0.1 0.15 Displacement, in Voltage, V -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 Displacement, in Voltage, V
Page 15 Read page 15 as text
14 CHAPTER 2. NATURE OF MATERIALS 2.1. See Section 2.2.1. 2.2. See Section 2.1. 2.3. See Section 2.1.1. 2.4. See Section 2.1.1. 2.5. See Section 2.1.2. 2.6. See Section 2.2.1. 2.7. See Section 2.1.2. 2.8. See Section 2.2.1. 2.9. See Section 2.2.1. 2.10. For the face-center cubic crystal structure , number of equivalent whole atoms in each unit cell = 4 By inspection the diagonal of the face of a FCC unit cell = 4r Using Pythagorean theory: (4r) 2 = a 2 + a 2 16r 2 = 2 a 2 8r 2 = a 2 r a 2 2 2.11. a. Number of equivalent whole atoms in each unit cell in the BCC lattice structure = 2 b. Volume of the sphere = (4/3) r 3 Volume of atoms in the unit cell = 2 x (4/3) r 3 = (8/3) r 3 By inspection, the diagonal of the cube of a BCC unit cell = 4r = a a a 2 2 2 = a 3 a = Length of each side of the unit cell = 3 4 r c. Volume of the unit cell = 3 3 4 r cell the of volume unit total cell unit the in atoms of volume APF = 3 3 ) 3 / 4 ( . ) 3 / 8 ( r r = 0.68
Page 16 Read page 16 as text
15 2.12. For the BCC lattice structure: 3 4 r a Volume of the unit cell of iron = 3 3 4 r = 3 9 3 10 124 . 0 4 x x = 2.349 x 10 -29 m 3 2.13. For the FCC lattice structure: r a 2 2 Volume of unit cell of aluminum = 3 ) 2 2 ( r = 3 ) 143 . 0 2 2 ( x =0.06616725 nm 3 = 6.6167x10 -29 m 3 2.14. From Table 2.3, copper has an FCC lattice structure and r of 0.1278 nm Volume of the unit cell of copper = 3 ) 2 2 ( r = 3 ) 1278 . 0 2 2 ( x = 0.04723 nm 3 = 4.723 x10 -29 m 3 2.15. For the BCC lattice structure: 3 4 r a Volume of the unit cell of iron = 3 3 4 r = 3 9 3 10 124 . 0 4 x x = 2.349 x 10 -29 m 3 Density = nA V N C A n = Number of equivalent atoms in the unit cell = 2 A = Atomic mass of the element = 55.9 g/mole N A = Avogadro’s number = 6.023 x 10 23 2 55 9 2 349 10 6 023 10 29 23 x x x x . . . = 7.9 x 10 6 g/m 3 = 7.9 Mg/m 3 2.16. For the FCC lattice structure: r a 2 2 Volume of unit cell of aluminum = 3 ) 2 2 ( r = 3 ) 143 . 0 2 2 ( x =0.06616725 nm 3 = 6.6167x10 -29 m 3 Density = nA V N C A For FCC lattice structure, n = 4 A = Atomic mass of the element = 26.98 g/mole N A = Avogadro’s number = 6.023 x 10 23 23 29 10 023 . 6 10 6167 . 6 98 . 26 4 x x x x = 2.708 x 10 6 g/m 3 = 2.708 Mg/m 3 2.17. N V nA A C For FCC lattice structure, n = 4 V c = 23 6 10 023 . 6 10 89 . 8 55 . 63 4 x x x x = 4.747 x 10 -29 m 3 APF = 0.74 = 29 3 10 747 . 4 . ) 3 / 4 ( 4 x r x r 3 = 0.2097 x 10 -29 m 3 r =0.128 x 10 -9 m = 0.128 nm
89 more pages in the full document
Unlock it once and it stays in your library, ready to chat with or turn into flashcards.
Unlock the full documentMore Civil Engineering study materials
See all
Textbook GuidesSolution Manual for Materials for Civil and Construction Engineers, 4th Edition
Civil Engineering
136 pagesMay 2025
Textbook GuidesSolution Manual for Transportation Engineering and Planning, 3rd Edition
Civil Engineering
78 pages92downloadsFeb 2025
Textbook GuidesReinforced Concrete Design, 9th Edition Solution Manual
Civil Engineering
198 pages65downloadsFeb 2025
Exam GuidesPrinciples Of Foundation Engineering, 8th Edition Test Bank
Civil Engineering
166 pages49downloadsFeb 2025
Textbook GuidesSolution Manual for A First Course in the Finite Element Method, 6th Edition
Civil Engineering
644 pagesMay 2025
Past ExamsThe CE Shop Construction Final Exam With Answers (100 Solved Questions)
Civil Engineering
55 pagesMay 2025
Textbook GuidesSolution Manual for Structural Steel Design, 6th Edition
Civil Engineering
511 pagesMay 2025
Textbook GuidesSolution Manual For Structural Wood Design: ASD/LRFD, 2nd Edition
Civil Engineering
268 pagesMay 2025
Study this document with CramX