| Discovered X-rays November 8th, 1895 Received the First Nobel Prize in Physics in 1901 |
| Light-tight cathode tube produced fluorescence of nearby chemical-coated cardboard screen Roentgen realized that cathode ray tube emitted “something” new “Something” passed through objects opaque to light, was invisible, and caused fluorescence Roentgen saw bones in his hand on cardboard screen He decided to call it X-ray for “unknown ray” A form of electromagnetic energy with a very short wavelength of .5 to .06 Angstrom Short wavelength allows x-rays to penetrate matter, unlike light rays Smaller wavelength = more energy |
Characteristics of X-Rays | X-rays have short wavelength, travel at speed of light, in straight path and cause ionization of matter X-rays can be absorbed, pass through, or be scattered by tissue Shades of gray are produced in relation to the amount of x-rays which are absorbed by the object being imaged and the remaining x-rays which reach the imaging medium |
| X-ray tube consists of an evacuated glass tube with cathode and anode terminals Cathode tungsten filament is heated to incandescence, giving off electrons Electrons bombard positively charged anode target, and x-rays are emitted |
| Ionizing radiation is radiation that has enough energy to remove electrons from atoms or molecules. Forms of ionizing radiation include X-Rays, Gamma Rays, Alpha particles, Beta particles and Neutrons. X-Rays, nuclear medicine studies, fluoroscopy and CT involve ionizing radiation |
| Photographic effect of x-rays produces film image, a representation of variable tissue densities and contours Scattered x-rays darken film and degrade image Radio-opaque tissue is denser, absorbs more x-rays, and appears as whiter image on film Radiolucent tissue is less dense, absorbs less x-rays and appears as darker image on film We don’t see x-rays, we see the radiograph Radio-opaque = basically a denser material, soaks up the energy and leaves the film white |
| A black film would be overexposed A white film would be underexposed Look for different densities in any film you are reading be it plain film or CT. For example you are reading a film of the pelvis, the pelvic girdle would white, pelvic organs shades of gray, bowel gas black |
| The image “spreads” or magnifies causing detail to be lost When the object creating the image is closer = more detail and closer to actual size |
| Patients cannot hold still long enough to obtain an image from x-rays alone Cassette contains fluorescent screens which glow when activated by x-rays and this light is used to expose the film Less radiation and exposure times are needed The “grid” cuts down on scatter effect on film – like a lens Can’t use glass, so need to use lead grid “honeycomb” for x-rays to go through to focus the beam and gets rid of scattering to make a clear image The image is taken much quicker than when it was first developed, which also clears up the image |
| What we study are radiographs, images, or films, not X-rays or electromagnetic waves The patient is placed between the x-ray tube and the film cassette. The body part closest to the cassette is magnified the least and has the sharpest boundaries |
| PA chest film, the x-rays pass posterior to anterior body part studied is closest to film, less magnification Lateral films are named for part closest to the film Posterior to anterior position: for heart and lung clear imagine (PA x-ray) Anterior to posterior position: for spine and muscles around it (AP x-ray) *describes the way the rays are going Left side: for best heart image or left lung Right side: for best right side tissues |
| Portable x-ray machine Chest X-ray must be Anterior posterior (AP) Images are never as good as in department Limited information- not as precise More expensive – but don’t tell the patient that Only reason for x ray in the room: if the patient cannot leave the room Since AP x ray, can’t see heart and lungs because it is directed towards spine and musculature |
| PA (posterior to anterior) Radiolucent lungs Radio-opaque bony thorax Intermediate density mediastinum with important contours
|
| KUB- kidneys, ureter, bladder Radiolucent bowel gas pattern Radiodense spine and pelvis or calcifications Intermediate density soft tissue viscera with important contours
|
| No actual “film” is required X-rays strike a phosphor plate and a photomultiplier intensifies the image. Data is recorded in a digital format, just like digital photography Resulting image can be viewed on a monitor screen or can be transferred to radiographic film Digital allows to send it anywhere, make many copies, and easier to store |
Advantages of Digital Radiography | Digital images require less storage space Multiple monitors can look at the same image at the same time Much more difficult to “lose the films” Images can be transmitted electronically and copies are easily generated. The view that is generated can be altered by the computer (Contrast and Brightness) |
Disadvantages of Digital Radiography | Hospitals already have fully functional film based imaging equipment and film library The new equipment is expensive – you cannot read diagnostic studies on a simple computer monitor Images may not quite as sharp and precise |
| Common radiological technique that allows real-time visualization A continuous beam of x-rays pass through the patient to form an image on a fluorescing screen which is amplified electronically and viewed on a television screen Common procedures include: Upper GI, Lower GI (barium enema) and many interventional procedures X-ray tube is below patient Film changer and image intensifier above patient Table can be tilted, patient can be rolled side to side |
| Any substance that is radio-opaque will absorb x-rays and show up as white in radiographs Different types of contrast material can be given orally, rectally, intravenously or injected into a specific space All forms of contrast have advantages and disadvantages |
| Outlines structures in the GI tract Can be administered from either end, depending on what you want to see Barium sulfate or iodinated water soluble Goes into the GI tract, stays in the GI tract – is not absorbed |
| Type of GI contrast Barium sulfate Extremely dense, provides good images Slow to be excreted - sticky stuff Contra-indicated where spillage into a body cavity is possible Must be dilute for CT scan – Redi Cat® Tastes terrible |
Iodine Based Water Soluble Contrast | Type of GI contrast Iodine based water soluble contrast OK if spilled into peritoneum or mediastinum Somewhat less dense, therefore gives slightly less detail Toxic to lung tissue, must be used carefully if there is a risk of aspiration Tastes terrible |
| Allows precise imaging of blood vessels or urinary tract Shows shape of vessels and any extravasation Iodinated compounds are most common, carbon dioxide can be used for angiography Materials containing Iodine are toxic to the kidneys Goes into the bloodstream, excreted in urine, does not transfer to any other location No taste Shows leaks (extravasation) and spaces of urinary tract Why do we choose CO2? Most other gases are dangerous (N for example can prevent heart from beating), CO2 is instantly removed from the body (O2 is slower) because attaches to Hb and taken out of circulation Examples: Renal Artery Arteriogram and Intravenous Pyelogram |
Digital Subtraction Angiography | Initial image to identify surrounding structures Repeat images with IV contrast have static portions of image removed Clarifies images of structures being studied Characteristic appearance Skull is very dense, so getting a clear picture of arteries using x rays= hard No contrast photo than photo with contrast and the computer subtracts the first image from the second one |
| Narrow beam of high frequency sound waves is produced by a vibrating crystal Sound waves are directed into the body and reflected back dependent upon tissues differing acoustic impedance The crystal in the transducer acts as a transmitter and a receiver Crystal that gives off and receives wanes and get photo from it Acoustic impedance: how sound “bounces” The tech’s hand is controlling the transmitter and receiver (acts as both) |
| The transducer records echoes reflected back when the sound wave strikes an interface between two tissues that have different acoustic properties This data is then analyzed by a computer to create a digital image Ultrasound can displayed as static images or as multiple video images that permit movement in real time US works well with fluid filled cavities |
| Images are based on internal echoes due to acoustic interfaces May be described as hypoechoic, isoechoic, or hyperechoic Solid tissue, tumors, fat or fibrous tissue show as light areas Anechoic – echo-free due to absence of acoustic interfaces; no sound interfaces Sonolucent - cyst or fluid-filled viscus shows as a dark area Acoustic Shadowing: Echogenic objects have differing amounts of acoustic shadowing – This may be described as “characteristic” |
| No ionizing radiation – freely used in obstetrics, pediatrics, and multiple evaluations Safe - no evidence as yet to indicate adverse effect on human tissue at intensity level currently used Multi-planar imaging – axial, sagittal, oblique planes Ability to differentiate cystic, solid, and complex tissue Cost-effective (cheap) Easily portable “Real-time” analysis and procedures |
| Air and bone produce extreme acoustic impedance; most sound is reflected prohibiting sound penetration Images not as clear as CT or MRI Very operator dependent- clarity of objects/objects' views |
| Ultrasound-guided biopsy of a breast mass for example | Shows the needle entering, inserting, and exiting the tissue |
| Ultrasound of abdominal aorta for example Doppler effect is used to calculate the velocity of the moving blood Wave form at bottom shows changes in velocity Checks the speed of the sound wave before and after and based off of the velocity can tell how fast something is moving, especially for a fluid Also color Doppler US, where color is added via computer |
| CT produces cross-sectional images by scanning a slice of tissue from multiple angles with a narrow X-Ray beam The computer then calculates the amount of radiation absorbed at each point in the rotation for the various elements in the tissue that was scanned It then displays the CT reconstructions as a gray scale image on a monitor Older name for CT: Computed Axial Tomography (CAT) |
CT: How the Image is Created | Electrical pulses are analyzed by a computer and the x-ray absorption for each voxel of body is calculated, producing image of black, white, and varying shades of gray Involves higher level math– the most complicated Sudoku you ever imagined A picture is then created where very dense tissues are white (bone), intermediate dense tissues are gray (liver), and least dense tissue is black (air) Images can be viewed on a screen or printed on specialized x-ray film Usually printed on film for storage |
| A newer technology, it is faster and can be used to develop three dimensional reconstruction in planes other than axial Then patient moves through at constant speed as it continuously rotates to take slices Continual CT scanning is performed as patient moves through the gantry Requires an entirely different (and more expensive) type of scanner |
| Next generation scanners perform multiple slices per rotation and provides software programming for instantaneous three-dimensional images Extremely fast scans Newer and more expensive machinery Spiral scanner, but get several individual slices at once |
| CT is extremely sensitive to slight differences in tissue density(1%) In comparison screen or film radiography requires at least a (5%) difference Gives excellent images and a wealth of information Available in some form in nearly any hospital |
| Expensive High demand may mean a long wait for imaging studies Ionizing radiation Could be considered “over utilized” |
| IV contrast Helps to differentiate vascular from nonvascular structures Differences in the degree of contrast over time helps characterize lesions Also helps define structures in urinary tract Oral contrast Helps to delineate the GI tract- stays in GI tract Must not be too dense Barium is too dense- best for only a single image taken at a time; we can’t use this for a CT because the CT is too complex |
Basic Rules of Orientation | No matter what imaging method is involved or what part of the body you are looking at, if the image is axial it should be displayed the same way The patient’s right side to your left and vice – versa Anterior is up, posterior is down |
Manipulation of CT Images | CT images can be manipulated to enhance visualization of lung parenchyma, mediastinum or bone by changing “window” settings CT scanner has buttons for lung, heart, etc. windows to see those structures better Example: lung window.. Can’t see bone as well or other things |
| Produced by “stacking” contiguous images from individual slices (CT) Even more higher level math Involves image averaging which gives limited detail 3D fracture reconstruction is particularly useful for orthopedic surgery 3D CT Angiography |
Magnetic Resonance Imaging (MRI) | Essentially imaging of protons Patient lies on a gantry within a magnetic field Hydrogen protons align themselves within the external magnetic field They then absorb energy from broadcast radio waves When the broadcast stops the protons send out new radio waves that can be detected and converted to images based on how many protons are present in any given area Signal intensity reflects number of hydrogen atoms Bones- not much detail because don't contain water |
| If the radio receivers listen early when the protons broadcast they create images called T1 weighted , if they listen later during the process the images are called T2 Image is determined by H+ atoms or water content, not tissue density as with x-ray Terminology includes high or low signal, not radiolucent or radiodense One scan can produce images in multiple planes Use T1 vs. T2 depending on what you want to see When you order a scan, must pick T1 or T2 scan, not both simultaneously CT scans can produce different windows from one image… MRI you can’t produce multiple images, only have T1 scan or T2 scan |
| Gadolinium is a rare earth element with atomic number 64 It is magnetically active and can be used to enhance contrast between tissues, especially in T1 images It is injected into the bloodstream during the procedure and helps with imaging tumors, infections, and acute stroke Example: MR Angiography |
| No ionizing radiation No known health hazard Multi-planar – axial, sagittal, coronal, oblique and other angles. Soft tissue contrast is excellent Less affected by patient’s body habitus Gadolinium – contrast utilized, well tolerated Bigger person can still get good images with MRI, unlike x-ray X ray- the bigger the person the more energy and the image is not clear and all white |
| Long scanning times Claustrophobia – “Open MRI” images do not give the same detail as closed tube Contraindicated with pacemakers and ferromagnetic materials Non-ferrous metals interfere with image quality. Respiratory and cardiac motion are problematic High cost |
| CT images are produced by X-rays, MR images are produced by magnetic fields. CT/x-ray contrast agents include barium sulfate or iodinated compounds, MRI uses gadolinium Fat in MRI appears white, Bone in CT appears white CT is excellent for bone, MRI is excellent for soft tissue |
| Common indications for CT imaging: Trauma, intracranial hemorrhage, fracture detection and evaluation, spine alignment, detect foreign bodies in joints, dx of primary and metastatic neoplasms, the gold standard for axial images Current uses of MRI: Has become the modality of choice for non urgent imaging of the central nervous system and spine Also first line of imaging for most conditions of musculoskeletal system Good for soft tissue injuries of knee, ankle, shoulder Long term back pain, psychological issues, muscle, tendon, cartilage, anything other than bone |
| In radiography ionizing radiation pass through the tissue to produce an image In Nuclear Medicine the patient ingests or is injected with a radiopharmaceutical that emits radiation and an image is created from the Gamma radiation emitted from within the patient |
Radioisotope Scanning (Nuclear Medicine) | adioactive isotope is given intravenously or by mouth and uptake is imaged with a gamma camera |
Nuclear Medicine Procedure Types | Radioisotopes such as technetium are bound to a chemical substance which normally accumulates in a specific organ TC attachment to – thyroid, bone, lung, etc. Patients red or white blood cells can be “tagged” to scan for bleeding or infection RBCs can see where you are bleeding WBCs can see where you have an infection |
Nuclear Medicine Contrast | The amount of ionizing radiation to the patient is similar to that in a plain radiograph The injected radionuclide does not produce the side effects or complications seen with radiographic iodinated contrast agents The physiologic map images produced by some nuclear medicine procedures allows change to be detected earlier than plain radiographs No worse than having an x ray, actually better than iodine contrast |
Nuclear Medicine: Organ Physiology | Abnormal radionuclide images demonstrate hot spots (increase in uptake) or cold spots (decreased uptake) Images are excellent for documenting organ physiology but lack in anatomic information Plain film studies can be useful for correlative purposes Can do an x-ray and nuclear study and compare them Thyroid nodule, bone scans, etc. Pulmonary Embolism: see an area of less perfusion (small and big areas) that tells us that blood flow is affected- can’t see this on an x ray Could see on simple CT of chest or arteriogram is large enough, perfusion scan is best way to dx |
Hepatobiliary Iminodiacetic Acid or HIDA Scan | HIDA is injected, IV, excreted by liver into biliary tree, enters the gallbladder and flows into the bowel With cholecystitis, the cystic duct is blocked, and there is no visualization of the gallbladder, even on delayed images Normal: at 15 minutes can start to see gallbladder, at 20 minutes the gallbladder is larger Abnormal: shows that the gallbladder is not filling and is abnormal Cannot see this on CT or MRI, only with nuclear medicine |
| Used in Malignant Melanoma and Breast Cancer Cases Allows removal of the first lymph node that drains the tumor site Designed to go into lymphatic system Breast cancer and melanoma – both spread to lymph nodes easily and so should remove these If we know where the tumor is you can find the lymph nodes that are affected because it drains to those ones |
Single Photon Emission Computed Tomography (SPECT) | Specialized gamma camera rotates around the patient to produce a tomographic image Used in cardiac imaging, cerebral perfusion scans Radio tracer in the blood and taking sliced images of that Shows blood flow |
Positron Emission Tomography (PET) | Evaluates how cells use glucose Fluorodeoxyglucose (FDG), a radioisotope, is given to patient, concentrates in tissue according to metabolic rate Breaks down to produce gamma rays (Positron Emission) Can be detected by a PET CT scanner for 3D images Takes specialized sugar and attach FDG to it, and when broken down/metabolized it gives off radiation Shows how much glucose is being broken down |
| Oncology - utilized to evaluate for metastatic disease and for post therapy follow-up evaluation Cardiology - screening for coronary artery disease and myocardial perfusion Neurology - stroke evaluation and to identify epileptic foci for surgical intervention Potential future uses are too numerous to list Examples: Lung cancer staging, responses to therapies (cancer especially), myocardial viability |